20–240W Low-Glare Linear LED Tunnel Light
The T.61X linear LED tunnel light uses an internal anti-glare optical panel behind a tempered-glass face to create an even, softer light-emitting surface. Its long-profile design supports continuous linear installation through tunnels and passages.
T.613 and T.614 models cover a series power range of 20–240W, with IP66 protection and a 110° optical distribution. Choose the length, color temperature and dimming configuration to suit your lighting layout.
Product Specifications
| Attribute | Description |
|---|---|
| Product Series | T.61X — T.613 / T.614 |
| Series Power Range | 20–240W |
| Housing | High-strength aluminum alloy profile |
| Optical Design | Tempered-glass face with an internal anti-glare optical panel |
| Optical Distribution | 110° |
| Luminous Efficiency | 100–135 lm/W |
| Input Voltage & Frequency | 176–265V AC, 50/60Hz |
| Control Options | Constant-on lighting / 0–10V dimming |
| Optional Control Configuration | DALI driver; 0–10V or reverse 10–0V dimming control, according to the selected power supply |
| Color Temperature | 3000K / 4000K / 5000K |
| Standard Length Options | 0.5m / 1m; the model comparison below lists the 1m configurations |
| Custom Lengths | 1–6ft available on request; confirm the matching wattage and configuration |
| Mounting Options | Angle-adjustable brackets; optional positioning-slot mounting parts |
| Luminaire Ingress Protection | IP66, using structural sealing |
| Impact Resistance | IK07 |
| Safety Class | Class I |
| Corrosion Protection | WF2 |
| Operating Temperature | −45°C to +50°C |
| Ambient Humidity | 10–95% RH |
Product Model Comparison
| Specification | T.613 | T.614 |
|---|---|---|
| Dimension Drawings | ![]() | ![]() |
| Power Range | 20–120W | 150–240W |
| Dimensions (L × W × H) | 1000 × 126 × 140mm | 1000 × 126 × 140mm |
| Weight | 3.1–3.5kg | 4.4kg |
| Luminous Efficiency | 100–135 lm/W | 100–135 lm/W |
| Optical Distribution | 110° | 110° |
Low-Glare Optics & Linear Product Design

Low-Glare Optics with an Even Luminous Surface
An internal anti-glare optical panel works with the tempered-glass face to produce a uniform, softer light-emitting surface along the luminaire.
This design suits continuous lighting layouts where the appearance of the luminous surface matters. Assess glare together with the mounting position, viewing direction and selected light output.

Structurally Sealed Aluminum Housing
The closed-body design uses structural sealing to achieve IP66 ingress protection. The high-strength aluminum alloy profile forms the main housing, with tempered glass over the optical surface.
IK07 impact resistance, Class I electrical protection and WF2 corrosion protection are specified for the series. Select the installation position and hardware to suit the operating environment.

Continuous Linear Installation and Length Options
The long-strip design supports continuous linear lighting arrangements. Standard housing lengths are 0.5m and 1m, with custom lengths from 1ft to 6ft available on request.
The model comparison above shows the 1m T.613 and T.614 configurations. Specify your required length and wattage together so the housing, light output and driver configuration can be matched.

Angle Adjustment and Positioning Options
The mounting illustration shows 60° adjustment to either side of the central position, allowing the luminaire direction to be set for the planned layout. Positioning-slot mounting parts are also available as an option.
Choose the mounting arrangement together with the control system. Constant-on operation, 0–10V dimming and optional DALI drivers support different project requirements; reverse 10–0V control is available with a suitable power supply.
110° Optical Distribution
Use the 110° distribution together with the selected mounting angle and luminaire spacing when planning coverage. Confirm light levels, uniformity and glare performance against the project’s lighting design.
Where to Use the 20–240W Low-Glare Linear LED Tunnel Light
The T.61X series suits linear lighting layouts in tunnels, corridors, underground parking areas and large indoor shopping centers. Match the length, wattage, mounting arrangement and controls to the space.
Urban Tunnels
Continuous linear arrangements along enclosed urban routes. Review luminaire spacing, aiming direction and output to meet the tunnel’s lighting requirements.
Corridors and Underground Passages
Linear lighting along pedestrian circulation routes where an even luminous surface is part of the design. Select the housing length to suit the available mounting space.
Underground Parking Areas
Lighting for parking circulation lanes and connecting areas. Coordinate mounting positions and dimming controls with the parking layout and required light levels.
Shopping Center Circulation Areas
Linear arrangements in large indoor shopping centers. Choose the color temperature, light output and control interface for the interior lighting plan.
AI-generated application illustrations. Actual luminaire configuration and installation depend on the project design.
Request a Quote for the 20–240W Low-Glare Linear LED Tunnel Light
Share your required length, wattage, quantity, layout dimensions, mounting details and dimming interface. Our team can review suitable T.61X models, length options and control configurations for your project.