20–240W Adjustable-Mount LED Tunnel Light

The T.62X LED tunnel light combines a ±90° adjustable bracket with four housing sizes covering 20–240W. Set the mounting angle to suit the tunnel profile and planned luminaire position.

A die-cast aluminum body, tempered-glass optical cover and IP66 protection suit urban tunnels, highway tunnels and pedestrian passages. Select the beam distribution, color temperature and dimming configuration for your project.

20–240W
Series power range
±90°
Bracket angle adjustment
IP66
Luminaire protection
4 sizes
T.621 / T.622 / T.623 / T.624

Product Specifications

AttributeDescription
Product SeriesT.62X — T.621 / T.622 / T.623 / T.624
Series Power Range20–240W
HousingIntegrated high-pressure die-cast aluminum alloy
Optical CoverTempered glass
LED Options3030 / 5050 LEDs
Mounting AdjustmentAdjustable bracket; ±90°
Optical Distributions 150° × 85°
Input Voltage & Frequency90–305V AC, 50/60Hz
Control OptionsConstant-on lighting / 0–10V dimming
Optional Dimming Interfaces0–5V / 0–10V / DALI / 485; specify the required driver configuration
Color Temperature2700K / 3000K / 4000K / 5000K
Optional Tunable WhiteDual-CCT dimming and color temperature adjustment: 2200–6000K
Luminaire Ingress ProtectionIP66
Impact ResistanceIK08
Safety ClassClass I 
Corrosion ProtectionWF1
Operating Temperature−45°C to +40°C
Ambient Humidity10–95% RH

Product Model Comparison

SpecificationT.621T.622T.623T.624
Dimension Drawings
Power Range20–60W50–120W100–150W150–240W
Dimensions
(L × W × H)
251 × 106 × 122mm251 × 156 × 156mm301 × 156 × 168mm352 × 156 × 178mm
Weight1.4kg2.5kg3.05kg4.12kg
Optical Distributions150° × 85°150° × 85°150° × 85°150° × 85°

Adjustable Mounting & Product Design

±90° Adjustment for On-Site Aiming

The mounting bracket allows the luminaire angle to be adjusted through ±90°. This gives installers flexibility to aim the light from the chosen mounting position.

Select the angle together with the beam distribution, mounting height and spacing. Check the final arrangement against the tunnel's lighting requirements.

Die-Cast Aluminum Body with Cooling Fins

The integrated housing uses high-pressure die-cast aluminum alloy. The finned rear structure supports heat dissipation within a compact body.

IP66 ingress protection, IK08 impact resistance and WF1 corrosion protection support use in tunnel environments. Four body sizes allow the luminaire to be selected for the required power range and available installation space.

T.62X adjustable-mount LED tunnel light product view.

Tempered-Glass Protection for the Optical Surface

A tempered-glass cover separates the optical components from the tunnel environment, helping limit direct exposure to exhaust deposits and other contaminants.

The optical distribution is 150° × 85°. Review the selected optics and aiming angle together when assessing coverage, uniformity and glare.

Dimming and Color Temperature Options

Specify constant-on operation or a dimming configuration to suit the lighting controls. Optional interfaces include 0–5V, 0–10V, DALI and 485, depending on the selected driver.

Fixed color temperatures include 2700K, 3000K, 4000K and 5000K. A dual-CCT configuration with dimming and adjustment from 2200K to 6000K is also available as an option.

150° × 85° Optical Distribution

Polar photometric distribution curve with red and blue intensity traces
Photometric Distribution Curve

The 150° × 85° optical distribution applies to the T.621, T.622, T.623 and T.624 models. Review tunnel width, mounting position, installation height and luminaire spacing when planning the layout. Confirm the final wattage, aiming angle and light levels with a project lighting calculation.

Where to Use the 20–240W Adjustable-Mount LED Tunnel Light

The T.62X series serves tunnel and passage lighting projects where mounting angle, beam distribution and available space need to work together. Select the model and control configuration for the lighting layout.

AI-generated illustration of an urban road tunnel with bracket-mounted rectangular LED lights.

Urban Road Tunnels

For enclosed urban routes where luminaire position and aiming angle must suit the tunnel profile. Choose the power range and optics to match the required light levels and uniformity.

AI-generated illustration of a highway tunnel illuminated by rows of rectangular LED luminaires.

Highway Tunnels

For highway tunnel projects requiring coordinated luminaire spacing and lighting control. Review the selected model against the design requirements for each tunnel zone.

AI-generated illustration of an underground pedestrian passage with high-mounted rectangular LED lights.

Pedestrian & Underground Passages

For pedestrian routes and underground passages with limited installation space. Compact models and an adjustable bracket help fit the proposed mounting arrangement.

AI-generated illustration of an existing concrete tunnel fitted with rectangular LED lights and organized cable conduits.

Existing Tunnel Lighting Upgrades

For projects assessing an LED replacement for existing tunnel luminaires. Compare the mounting clearances, wiring, controls and lighting performance before selecting the replacement wattage.

AI-generated application illustrations. Actual luminaire configuration and installation depend on the project design.

Request a Quote for the 20–240W Adjustable-Mount LED Tunnel Light

Share your tunnel dimensions, mounting position, installation height, luminaire spacing, quantity and control requirements. Our team can review suitable T.62X models, beam distributions and dimming options for your project.

滚动至顶部

Request a Quotation

Tell us what you need for your lighting project.

Contact Form Demo
Let’s Talk About Your Project

Share your preferred product, quantity and project requirements. Our team can help you review the configuration.